500kw diesel power generator
The specification of power generator:
Genset model:HX8GF-HX1200GF
Type:open/sound proof/weather proof/trailer type
Generatort output power range:8kw-1200kw
Rated voltage:220/380V,230/400V,240/415V,120/240V as required
Frequency:50/60HZ
Power factor:0.8
Rated speed:1500/1800rpm
Output type:AC three phase/single phase
Alternator:brushless
Frequency:<3%
Frequency at stable state:<0.5%
Frequency deviation at instantaneous state:≤+10%
Frequency return time:≤3s
Voltage deviation at stable state:≤±1%
Voltage deviation at instantaneous state:≤+20%
Voltage return time:≤4s
Voltage modulation:≤0.3%
The specification of the diesel engine:
Brand | Cummins,Perkins,Lovol,Deutz,Ricardo,Volvo,Styre,Wudong 135,138 .etc |
Cooling Method | water cooled |
Rotating speed | 1500/1800rpm |
Governor system | electrical or mechanical governor |
Aspiration mode | natural aspirated or turbocharged |
Starting method | 12/24V DC electric starting |
Stroke | 4 stroke |
The specification of alternator:
Number of Phase: | 3 |
Connecting Type: | 3 Phase and 4 Wires, “Y” type connecting |
Number of Bearing: | 1 |
Power Factor: | 0.8 |
Protection Grade: | IP23 |
Altitude: | <1000m |
Exciter Type: | Brushless, self-exciting |
Insulation Class, Temperature Rise: | H/H |
Telephone Influence Factor (TIF): | <50 |
THF: | <2% |
Voltage Regulation, Steady State: | <±1% |
Alternator Capacity: | 37.5KVA |
Alternator Efficiencies: | 86.60% |
Air Cooling Flow: | 0.15m3/s |
Control system of power generator:
1) Automatic alarm system: the unit has the acousto-optics alarm system and arrestor for any situation as the start defeat, the water is over temperature, the oil pulls down, over speed, over load and over current.
2) Operation display:
a) Unit voltage, tri-phase load current and frequency display
b) Water temperature, oil pressure display
c) Fuel level, fuel temperature display
d) Audible and visual alarm lamps and buzzers
Standard configuration of power generator:
1) Starting system: DC alternator is used to start engine
2) Short circuit protection: MCCB air switch
3) Cooling system: combined cooling water tank fitted to meet the requirement of radiation at ambient temperature 40°C
4) Filter system: oil, fuel and air filter
5) Accessories: exhaust elbow, bellow, muffler
After sale-service of power generator: